หมวดหมู่ | 18.2 Flow meters for compressed air (โฟลว์มิเตอร์สำหรับการตรวจสอบลมรั่วในระบบ (อากาศอัด)) |
ราคา | 0.00 บาท |
สถานะสินค้า | พร้อมส่ง |
ลงสินค้า | 16 พ.ย. 2558 |
อัพเดทล่าสุด | 13 ก.ค. 2566 |
จำนวน | ชิ้น |
Product characteristics | ||||||||||||||
Compressed air meter | ||||||||||||||
Connector | ||||||||||||||
Process connection: R2 (DN50) | ||||||||||||||
Function programmable | ||||||||||||||
2 outputs | ||||||||||||||
OUT1: flow monitoring (binary), quantity meter (pulse), preset counter (binary) | ||||||||||||||
OUT2: flow or temperature monitoring (analogue or binary) | ||||||||||||||
flow monitoring | ||||||||||||||
Display range | ||||||||||||||
0...840 Nm³/h | ||||||||||||||
Measuring range | ||||||||||||||
2.3 (3)...700 Nm³/h *) | ||||||||||||||
Temperature monitoring | ||||||||||||||
Display range | ||||||||||||||
-12...72 °C | ||||||||||||||
![]() |
||||||||||||||
Application | Compressed air Air quality(ISO 8573-1): Class 141 (measuring error: see below, value A) Class 344 (measuring error: see below, value B) |
|||||||||||||
Pressure rating [bar] | 16 | |||||||||||||
Medium temperature [°C] | 0...60 | |||||||||||||
![]() |
||||||||||||||
Electrical design | DC PNP | |||||||||||||
Operating voltage [V] | 18...30 DC ¹) | |||||||||||||
Current consumption [mA] | < 110 | |||||||||||||
Protection class | III | |||||||||||||
Reverse polarity protection | yes | |||||||||||||
![]() |
||||||||||||||
Output function | OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programmable or analogue (4...20 mA scaleable) |
|||||||||||||
Current rating [mA] | 2 x 250 | |||||||||||||
Voltage drop [V] | < 2 | |||||||||||||
Short-circuit protection | pulsed | |||||||||||||
Overload protection | yes | |||||||||||||
Analogue output | 4...20 mA | |||||||||||||
Max. load [Ω] | < 500 | |||||||||||||
Pulse output | consumed quantity meter | |||||||||||||
![]() |
||||||||||||||
Flow monitoring | ||||||||||||||
Measuring range | 2.3 (3)...700 *) Nm³/h | 0.039 (0.04)...11.66 *) Nm³/min | 0.3...95.2 Nm/s | |||||||||||
Display range | 0...840 Nm³/h | 0.00...13.99 Nm³/min | 0.0...114.2 Nm/s | |||||||||||
Set point, SP | 5...700 Nm³/h | 0.09...11.66 Nm³/min | 0.7...95.2 Nm/s | |||||||||||
Reset point, rP | 2...697 Nm³/h | 0.04...11.61 Nm³/min | 0.3...94.8 Nm/s | |||||||||||
Analogue start point, ASP | 0...525 Nm³/h | 0.00...8.75 Nm³/min | 0.0...71.4 Nm/s | |||||||||||
Analogue end point, AEP | 175...700 Nm³/h | 2.91...11.66 Nm³/min | 23.8...95.2 Nm/s | |||||||||||
in steps of | 1 Nm³/h | 0.01 Nm³/min | 0.1 Nm/s | |||||||||||
Volumetric flow quantity monitoring | ||||||||||||||
Pulse value | 0.010...4000000 m³ | |||||||||||||
in steps of | 0.010 m³ | |||||||||||||
Pulse length [s] | ≥ 0.021 / ≤ 2 | |||||||||||||
Temperature monitoring | ||||||||||||||
Measuring range [°C] | 0...60 | |||||||||||||
Display range [°C] | -12...72 | |||||||||||||
![]() |
||||||||||||||
Flow monitoring | ||||||||||||||
Accuracy (within measuring range) | A): ± (3% MW + 0.3% MEW) / B): ± (6% MW + 0.6% MEW) ***) | |||||||||||||
Repeatability [% of the measured value] | ± 1.5 | |||||||||||||
Temperature monitoring | ||||||||||||||
Accuracy [K] | ± 2 **) | |||||||||||||
![]() |
||||||||||||||
Power-on delay time [s] | 1 | |||||||||||||
Flow monitoring | ||||||||||||||
Response time [s] | < 0.1 (dAP = 0) | |||||||||||||
Damping, dAP [s] | 0 - 0.2 - 0.4 - 0.6 - 0.8 - 1 | |||||||||||||
![]() |
||||||||||||||
Programming options | hysteresis / window function; NO / NC; current / pulse output; display can be rotated / deactivated; display unit, totalizer | |||||||||||||
![]() |
||||||||||||||
IO-Link Device | ||||||||||||||
Transfer type | COM2 (38.4 kBaud) | |||||||||||||
IO-Link revision | 1.1 | |||||||||||||
SDCI standard | IEC 61131-9 CDV | |||||||||||||
IO-Link Device ID | 270 d / 00 01 0E h | |||||||||||||
Profiles | no profile | |||||||||||||
SIO mode | yes | |||||||||||||
Required master port type | A | |||||||||||||
Process data analogue | 3 | |||||||||||||
Process data binary | 2 | |||||||||||||
Min. process cycle time [ms] | 4.1 ms | |||||||||||||
![]() |
||||||||||||||
Ambient temperature [°C] | 0...60 | |||||||||||||
Storage temperature [°C] | -20...85 | |||||||||||||
Max. relative air humidity [%] | 90 | |||||||||||||
Protection | IP 65 | |||||||||||||
![]() |
||||||||||||||
Pressure equipment directive | Article 3, section 3 - sound engineering practice | |||||||||||||
EMC |
|
|||||||||||||
Vibration resistance |
|
|||||||||||||
MTTF [Years] | 227 | |||||||||||||
![]() |
||||||||||||||
Process connection | R2 (DN50) | |||||||||||||
Materials (wetted parts) | stainless steel (304S15): FKM; ceramics: glass passivated; PEEK GF30; polyester; aluminium | |||||||||||||
Housing materials | PBT-GF 20; NBR; PC (polycarbonate); stainless steel (304S15); PTFE; Brass coated; FKM; aluminium powder-coated | |||||||||||||
Weight [kg] | 4.35 | |||||||||||||
![]() |
||||||||||||||
Display |
|
|||||||||||||
![]() |
||||||||||||||
Connection | M12 connector | |||||||||||||
Wiring
|
||||||||||||||
![]() |
||||||||||||||
Remarks |
|
ifm electronic, efector, เซนเซอร์ที่ใช้สำหรับกระบวนการผลิต, Process sensors, เซนเซอร์วัดการไหล, โฟลว์มิเตอร์, โฟลว์สวิทช์, โฟลว์เซนเซอร์, Flow switches, Flow sensors, Flow meters, SCM Allianze, SCMA, เอสซีเอ็ม อลีอันซ์, Siemens, Sick, Balluff, P&F, Turck
ผลิตภัณฑ์เซนเซอร์กลุ่มเซนเซอร์วัดการไหลของ ifm (efector) ร้อยละ 95% ยังผลิตที่ประเทศเยอรมนี ซึ่งต่างกับหลายๆ แบรนด์ที่ย้ายฐานการผลิตไปที่ประเทศจีนเพื่อลดต้นทุน ซึ่งอาจส่งผลให้มีโอกาสเกิดปัญหาของ QC ได้ และเซนเซอร์วัดการไหลหลายรุ่นของเรายังสามารถเทียบรุ่นกับเซนเซอร์วัดการไหลของยี่ห้อตลาดทั่วไป เช่น Siemens, Sick, Balluff, P&F, Turck ได้ทันทีโดยไม่ต้องทำการดัดแปลงขายึดหรือพื้นที่ติดตั้งใดๆ ทำให้ลูกค้าสามารถเลือกใช้เซนเซอร์วัดการไหลคุณภาพเยอรมนีของเราได้อย่างสะดวกรวดเร็ว และที่สำคัญในราคาที่ไม่แพงกว่าเซนเซอร์ที่ผลิตในจีน
// นโยบายการเปลี่ยนหรือคืนสินค้า บริษัทฯ ขอสงวนสิทธิ์ใช้นโยบายมาตรฐานเช่นเดียวกับการซื้อในช่องทางปกติ ท่านสามารถสอบถามได้ก่อนสั่งซื้อสินค้ากับพนักงานของเรา //
นโยบายการเปลี่ยน/คืนสินค้า
Return Policy
บริษัท เอสซีเอ็ม อลีอันซ์ จำกัด ยินดีรับเปลี่ยนหรือคืนสินค้าภายใน 7 วันหลังจากได้รับสินค้า ตามกรณีดังต่อไปนี้
1. ในกรณีที่ทางบริษัท เอสซีเอ็ม อลีอันซ์ จำกัด จัดส่งสินค้าให้กับลูกค้าผิดรุ่นจากการยืนยันการสั่งซื้อ ทางบริษัทฯ ยินดีที่จะรับเปลี่ยนและจัดส่งสินค้าที่ถูกต้อง ให้กับลูกค้าใหม่ภายใน 30 วันทำการ(ทั้งนี้ระยะเวลาการจัดส่งจะขึ้นอยู่กับสต๊อกของสินค้ารุ่นนั้นๆ) โดยไม่คิดค่าใช้จ่ายใดๆ
2. ในกรณีที่ลูกค้ามีความประสงค์จะเปลี่ยนสินค้า เช่น กรณีเปลี่ยนรุ่นของสินค้า ลูกค้าจะต้องทำการจัดส่งสินค้ากลับมายังบริษัทฯ โดยลูกค้าจะเป็นผู้รับผิดชอบค่าใช้จ่ายในการจัดส่งสินค้าคืน และสินค้าต้องไม่ชำรุดเสียหายจากการใช้งาน สภาพสินค้าอยู่ในสภาพพร้อมขาย มิฉะนั้นทางบริษัท จะสงวนสิทธิในการรับคืนสินค้าดังกล่าว(สภาพพร้อมขาย หมายถึง สภาพสินค้า/ตัวเครื่องและอุปกรณ์ต่างๆ ที่ไม่เกิดการเปลี่ยนแปลง เสียหาย และบรรจุอยู่ในหีบห่อบรรจุภัณฑ์ของสินค้านั้นๆ ในสภาพเดียวกันกับสภาพที่บริษัทฯ นำส่งให้ลูกค้า) ทางบริษัทฯ จะทำการตรวจสอบสินค้าก่อนจัดส่งสินค้าใหม่ให้แก่ลูกค้า
การจัดส่งสินค้ากลับไปยังลูกค้า ทางบริษัทฯ ขอจัดเก็บค่าใช้จ่าย ในการจัดส่งสินค้าใหม่แก่ลูกค้าตาม (สอบถามค่าจัดส่งได้จากพนักงานขาย)
3. ในกรณีที่มีการยกเลิกรายการสั่งซื้อ สินค้าจะต้องอยู่ในสภาพพร้อมขาย (สภาพพร้อมขาย หมายถึง สภาพสินค้า/ตัวเครื่องและอุปกรณ์ต่างๆ ที่ไม่เกิดการเปลี่ยนแปลง เสียหาย และบรรจุอยู่ในหีบห่อบรรจุภัณฑ์ของสินค้านั้นๆ ในสภาพเดียวกันกับสภาพที่บริษัทฯ นำส่งให้ลูกค้า) โดยมีค่าธรรมเนียมในการขอคืนเงิน ทางบริษัทฯขอสงวนสิทธิ์เรียกเก็บค่าดำเนินการขอคืนเงิน 10% ของยอดมูลค่าสินค้า ทางบริษัทฯ จะทำใบลดหนี้และโอน/ สั่งจ่ายเช็คยอด 90% กลับไปยังบัญชีบัตรเครดิตหรือบัญชีธนาคารของลูกค้าภายใน 30 วันทำการถัดไป นับจากวันที่บริษัทฯ ได้ทำการตรวจสอบและยืนยันการยกเลิกสินค้า
ทั้งนี้ลูกค้าจะต้องทำการจัดส่งสินค้ากลับมายังบริษัทฯ โดยลูกค้าจะเป็นผู้รับผิดชอบค่าใช้จ่ายในการจัดส่งสินค้าคืน ทางบริษัทฯ จะทำการตรวจสอบสินค้าและยืนยันการรับคืนสินค้าและเข้ากระบวนการการคืนเงินให้ลูกค้าต่อไป
4. กรณีลูกค้าส่งเครื่องมือไปสอบเทียบกับสถาบันสอบเทียบเครื่องมือหรือห้องแล็ปเอง ทางบริษัทฯจะไม่รับเปลี่ยน/คืนสินค้าหรือรับผิดชอบค่าเสียหายทุกกรณี (หากต้องการส่งเครื่องมือสอบเทียบ กรุณาแจ้งความประสงค์ได้ที่เจ้าหน้าที่ฝ่ายขายเพื่อติดต่อขอรับบริการจากทางบริษัทฯ)
5. ในกรณีที่ทางบริษัท เอสซีเอ็ม อลีอันซ์ จำกัด จัดส่งสินค้าชำรุดให้กับลูกค้า ลูกค้าสามารถติดต่อบริษัทฯ (ต้องติดต่อภายใน 3 วันตั้งแต่วันที่ท่านรับสินค้าทันที พร้อมเก็บบรรจุภัณฑ์ เช่นกล่องไปรษณีย์เดิม เพื่อทำการส่งกลับ หากเกินกว่า 3 วันหลังจากได้รับสินค้า ทางเราขอสงวนสิทธิ์ที่จะไม่รับเปลี่ยน/คืนสินค้า)